Failure analysis of a hydraulic press clamp


Por: Ossa, Edgar Alexander, Paniagua, Marco Aurelio

Publicada: 1 jun 2008
Categoría: Engineering (miscellaneous)

Resumen:
This paper describes the analysis and investigation of the causes of the failure of an hydraulic press jaw face grip. Analysis of the fractured surfaces indicated the creation of cracks due to stress concentrators as a result of defective design. On the other hand, metallographic examination revealed the presence of aligned clusters of primary carbides that along with the stress concentrators induced the premature failure of the grip.

Filiaciones:
Ossa, Edgar Alexander:
 Univ EAFIT, Dept Ingn Prod, Grp Invest Mat, Medellin, Colombia

Paniagua, Marco Aurelio:
 Univ EAFIT, Grp Invest Mat Ingn, Dept Ingn Prod, Medellin, Colombia
ISSN: 01206230
Editorial
IMPRENTA UNIV ANTIOQUIA, 67 N 53-108, BLOQUE 28, CIUDAD UNIV, UNIV ANTIQUIA, MEDELLIN, 00000, COLOMBIA, Colombia
Tipo de documento: Article
Volumen: Número: 44
Páginas: 30-35
WOS Id: 000255920200004

MÉTRICAS